HZKZ-50A Transformer Load and No Load Loss Characteristic Tester
video
HZKZ-50A Transformer Load and No Load Loss Characteristic Tester

HZKZ-50A Transformer Load and No Load Loss Characteristic Tester

Transformer On-No Load Characteristics Tester adopts the popular ARM processor in this year, with 168M basic frequency and 128m memory, which can be expanded to 4G memory card.
Product Details ofHZKZ-50A Transformer Load and No Load Loss Characteristic Tester

 

Transformer Load And No Load Loss Characteristic Tester

Transformer Load and No Load Loss Tester

Summary

Transformer On-No Load Characteristics Tester adopts the popular ARM processor in this year, with 168M basic frequency and 128m memory, which can be expanded to 4G memory card. Using 7-inch high-definition color touch panel, combined with emwin display interface so as to make the instrument interface being friendly and operated in a simple way, it can be operated through the touchscreen without keyboard. The instrument support database and can be exported through USB disk or transmitted to computer via data wire.

It can not only be used to test the on-no load parameters of transformer, but also measure the harmonic content and waveform in the field. The instrument can record the test curve of transformer under on-no load condition, then provide reliable basis for transformer fault analysis.

Tech Data

Voltage measurement range

0 500V phase voltage (line voltage is 800V)

Current measurement range

0 50A (support external CT to expand measuring range)

Measurement accuracy

{{0}}.2 percent (power factor 1.0-0.2); 1 percent (power factor 0.2 0.01)

Record Queries

When the test is completed, the results can be queried and exported to USB disk or uploaded to computer

The recorded number in database is displayed on the left and details of a record can be displayed on the right. Clicking the main scroll bar can scroll the screen up and down or left and right to display all the information. Selecting a record and clicking the print button can print the test results on the spot through the printer. Inserting a USB disk and clicking export to export the entire database to the USB disk (inserting USB disk needed to wait for two or three seconds, so the instrument can detect it). The USB disk database adopts Dbase3 database format and can be directly opened, edited and printed by excel spreadsheet. It does not need to install background management software, which makes the management more convenient for users.

image004

image006

image008

الوسم : HZKZ-50A Transformer Load and No Load Loss Characteristic Tester, China, suppliers, manufacturers, price, for sale, power transformer no load test, transformer no load losses test, load loss test of transformer, transformer noload tester, Transformer Routine Test, hzkz-50a, transformer losses tester, load and noload tester, transformer noload capacity tester